Thermo Fisher Scientific
ASM-IV Automatic Scrap Monitoring System
Automatic portal monitoring system that checks vehicles carrying scrap and metal on the way in and out, for scrap processing, mills and foundries.
The ASM-IV is an automatic monitoring system for scrap processing, mills and foundries, where vehicles carrying material are checked on the way in and out. Two sets of proximity sensors are included, and the System Control Unit shows abbreviated results from the 10 most recent scans in a colour-coded history banner.
- Configurable platform that prevents radioactive materials from entering scrap metal and metal processing workflows
- Multiple smaller, independent detector zones improve signal-to-noise and give vertical resolution to pinpoint the source
- Dynamic Background Suppression and vehicle profiling algorithm
- Remote monitoring of system health, daily scan event tracking and monthly reporting
- Current ASM II/III/SE users can upgrade with available kits
No prices online – you will receive a quotation with price and delivery time. Need accessories? Mention them in your request.

Authorised distributor in SwedenAll products from Thermo Fisher Scientific →
Technical data
| Models | 3KE, 6KV, 6KE, 12KV, 18KV, 6KD, 12KD, 18KD, 24KD |
|---|---|
| Vertical coverage | 838 mm to 3886 mm depending on model |
| Number of detectors | 2 to 16 depending on model |
| System detector volume | 47 to 378 litres depending on model |
| RDM sizes | Single: 23.60 litres, Double: 47.19 litres, Enhanced: 51.91 litres active volume |
| RDM enclosure assembly | Weatherproof, lead-lined stainless steel NEMA rated enclosures; 1/8-in lead shielding |
| RDM spacing | 4.2 m (14 ft) or less for best performance |
| Operating temperature | RDM −30 °C to +60 °C; SCU 0 °C to +40 °C |
| System Control Unit (SCU) | 12.1-in LCD touch screen, Ethernet (RJ45), two USB 2.0 ports, four relay outputs, four discrete inputs |
| Power requirements | 100 to 264 VAC RMS, 47 to 63 Hz |
| SCU dimensions | 406 × 356 × 108 mm, 8.7 kg |
| Regulatory compliance | UL/CSA/EN 61010-1; EN61326, EN55011; FCC subpart B (Class A); RoHS compliant |
Source: Thermo Fisher Scientific, ASM-IV brochure (2020). Full specifications are available in the documents.